Chongqing Steel structure engineering

contact us
Office Locations

We usually respond within 24 hours. Alternateively you’re welcome to connect us via whatsapp. 

No. 32, Juye Road, Jiulongpo District, Chongqing

+86 189 9647 2857

support@cqsses.com

DateJun 2024
Structure Type:Dual-level steel truss pedestrian bridge
FunctionConnects 3rd & 4th floors of Medical Complex and Science-Education Complex
Design ConceptFreestanding steel truss system (disconnected from main buildings)
LevelsTwo stacked trusses (each 4.5m clear height)

Key Structural Overview

📍 Location: Chongqing, China
🏗 Structure Type: Dual-level steel truss pedestrian bridge
🔗 Function: Connects 3rd & 4th floors of Medical Complex and Science-Education Complex

Engineering Highlights

 Innovative Disconnection: Seismic isolation via full structural separation from main buildings
✔ Precision Fabrication: Laser-cut box sections with ±1.5mm tolerance
✔ Wind Engineering: CFD-optimized truss profile for Chongqing’s high humidity & gusty conditions

“This walkway demonstrates how medical infrastructure can blend seismic resilience with architectural lightness.”
— Wenchen Lead Structural Engineer

Technical Specifications

1. Structural System

  • Design Concept: Freestanding steel truss system (disconnected from main buildings)

  • Spans: Total length 78.4m | Height 19.65m | Floor area 182.5m²

  • Levels: Two stacked trusses (each 4.5m clear height)

  • Lateral Resistance: Steel-reinforced concrete columns + truss action (designed as sway frame)

2. Material & Components

  • Primary Steel: Q355B grade

  • Columns: Steel-reinforced concrete with welded H-section cores

  • TrussesBox-welded sections (vertical load-bearing)

  • Floor BeamsBox-welded sections, rigidly connected to truss chords

3. Safety & Compliance

  • Design Life: 50 years (structure & seismic)

  • Seismic Rating:

    • Seismic class: Standard fortification

    • Intensity: 6° (PGA 0.05g)

    • Group: 1st

  • Fire Protection:

    • Safety class: Level 1 (primary members)

    • Fire rating: Level 2 (1.5h resistance for columns/trusses/beams)

4. Connection Technology

  • High-Strength Bolts:

    • Type: Shear-type (GB/T 3632-2008)

    • Grade: 10.9 (per JGJ82-2011)

    • Friction surface: Sandblasted (μ=0.5)

Why Choose Wenchen for Such Projects?

  • Hospital Experience: 12+ healthcare steel structure projects

  • Certifications: GB/ISO for medical facility construction

  • BIM Integration: Clash detection with MEP systems

Request the full technical dossierSupport@cqsses.com